Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burch, K.
Right arrow Articles by Constance, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burch, K.
Right arrow Articles by Constance, T.
American Journal of Hospital Pharmacy, Vol 48, Issue 1, 92-97
Copyright © 1991 by American Society of Health-System Pharmacists


Articles

Effect of an infusion device on the integrity of whole blood and packed red blood cells

KJ Burch, SJ Phelps, and TD Constance


The effects of the Gemini PC-2 linear peristaltic infusion device on the integrity of packed red blood cells (RBC) and whole blood products are reported. Thirty-eight units of blood products were infused at rates of 999, 100, 50, and 5 mL/hr under simulated clinical conditions. To evaluate the effect of hematocrit on cell survival, fresh and stored packed RBCs preserved with adenine-saline 3 (AS-3) and fresh and stored packed RBCs and fresh and stored whole blood preserved with citrate-phosphate-dextrose-adenine 1 (CPDA-1) were used. No two units tested came from the same donor. Plasma potassium and plasma free hemoglobin concentrations were determined before and after simulated infusion for 80 experimental runs. Preinfusion plasma potassium and free hemoglobin concentrations varied significantly among the blood products. Stored products were associated with higher plasma potassium and free hemoglobin levels than fresh units, both before and after infusion. Concentrations also differed significantly between AS-3-preserved and CPDA-1-preserved fresh and stored packed RBCs. Infusion did not change plasma potassium values appreciably under any conditions. Plasma free hemoglobin increased in the fresh products only. Donor-specific differences were significant for potassium but not for free hemoglobin. There was no significant effect of infusion rate on either biochemical marker. In all the experimental runs, less than 0.01% of cells were lysed. The Gemini PC-2 linear peristaltic infusion device delivered a variety of blood products at a wide range of infusion rates without inducing a substantial degree of hemolysis.
 






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Society of Health-System Pharmacists.