Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Patel, J.
Right arrow Articles by Carr, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Patel, J.
Right arrow Articles by Carr, L.
American Journal of Hospital Pharmacy, Vol 48, Issue 7, 1511-1514
Copyright © 1991 by American Society of Health-System Pharmacists


Articles

Activity of urokinase diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored in glass or plastic syringes

JP Patel, LT Tran, WJ Sinai, and LJ Carr


The effects of the diluent, the container, the i.v. set, and the drug concentration on the adsorption of urokinase to i.v. administration systems were studied, along with the compatibility of urokinase with plastic and glass syringes. Solutions of urokinase 1500 and 5000 IU/mL in 0.9% sodium chloride injection and 5% dextrose injection in glass and polyvinyl chloride (PVC) containers were sampled at 2 and 30 minutes. Administration sets were attached to PVC containers containing the urokinase-5% dextrose injection solutions, and samples were collected at 90 and 150 minutes. Glass and polypropylene syringes containing urokinase 5000 IU/mL in 0.9% sodium chloride injection or 5% dextrose injection were sampled at 0, 4, 8, and 24 hours. Urokinase activity was measured by an in vitro clot lysis assay. No urokinase diluted in 0.9% sodium chloride injection adsorbed to glass or PVC containers. For urokinase 1500 IU/mL in 5% dextrose injection, a loss of 15% to 20% occurred almost instantaneously in PVC containers; additional losses to the infusion sets were minimal. However, for urokinase 5000 IU/mL in 5% dextrose injection, no losses were observed in the PVC systems. No drug loss to glass bottles was seen for urokinase 1500 or 5000 IU/mL in 5% dextrose injection. Urokinase potency remained constant in polypropylene and glass syringes for 24 hours. To minimize urokinase sorption to PVC containers, higher concentrations of urokinase diluted in 5% dextrose injection should be used, provided that clinical safety and efficacy are not compromised. The use of 0.9% sodium chloride injection as a diluent also prevents sorption losses.
 






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Society of Health-System Pharmacists.