Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Taormina, D
Right arrow Articles by Starzl, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Taormina, D
Right arrow Articles by Starzl, T.
American Journal of Hospital Pharmacy, Vol 49, Issue 1, 119-122
Copyright © 1992 by American Society of Health-System Pharmacists


Articles

Stability and sorption of FK 506 in 5% dextrose injection and 0.9% sodium chloride injection in glass, polyvinyl chloride, and polyolefin containers

D Taormina, HY Abdallah, R Venkataramanan, L Logue, GJ Burckart, RJ Ptachcinski, S Todo, JJ Fung, and TE Starzl


The effects of the diluent, the storage container, light, and infusion through various types of tubing on the stability and sorption of FK 506 were studied. Solutions of FK 506 in 0.9% sodium chloride injection or 5% dextrose injection were stored at room temperature (24 +/- 2 degrees C) in glass i.v. bottles, polyvinyl chloride (PVC) minibags, and polyolefin containers. FK 506 solution in 0.9% sodium chloride injection was stored in plastic syringes at room temperature and either exposed to normal room light or stored in the dark. FK 506 solution in 5% dextrose injection was placed in plastic syringes and infused through PVC anesthesia extension tubing, PVC i.v. administration set tubing, and fat emulsion tubing over a two-hour period. The infused samples and samples collected from the containers and syringes at intervals up to 48 hours were analyzed for FK 506 concentration by high-performance liquid chromatography. FK 506 concentrations remained greater than 90% of initial concentration for admixtures in 5% dextrose injection stored in glass bottles for 48 hours and for admixtures in 5% dextrose injection or 0.9% sodium chloride injection stored in polyolefin containers for 48 hours. No change in concentration was measured for admixtures in 0.9% sodium chloride injection stored in plastic syringes, and exposure to light did not affect the stability of FK 506 solution. No substantial change in concentration occurred in FK 506 solution in 5% dextrose injection infused through PVC anesthesia extension tubing, PVC i.v. administration set tubing, or fat emulsion tubing. FK 506 admixtures prepared with 5% dextrose injection or 0.9% sodium chloride injection should be stored in polyolefin containers. If polyolefin containers are not available, solutions should be prepared with 5% dextrose injection and stored in glass bottles.
 






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Society of Health-System Pharmacists.