Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pluhator-Murton, M.
Right arrow Articles by Yatscoff, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pluhator-Murton, M.
Right arrow Articles by Yatscoff, R.
American Journal of Health-System Pharmacy, Vol 53, Issue 19, 2299-2303
Copyright © 1996 by American Society of Health-System Pharmacists


Articles

Extent of trace-element contamination from simulated compounding of total parenteral nutrient solutions

MM Pluhator-Murton, RN Fedorak, RJ Audette, BJ Marriage, and RW Yatscoff


The extent and sources of trace-element contamination during simulated manual and automated compounding of total parenteral nutrient (TPN) solutions were studied. Four experimental groups were prepared: (1) sterile water for injection as received from the manufacturer, (2) TPN bags manually filled with sterile water for injection, (3) TPN bags automatically filled with sterile water for injection, and (4) sterile water for injection manually added directly to sample vials (i.e., bypassing the TPN bag). After the bags had been stored for 16 hours at 4 degrees C, samples were analyzed for 66 trace elements by inductively coupled plasma-mass spectrometry. Of the 66 trace elements analyzed for, 3 (zinc, boron, and aluminum) were present as contaminants in each of the experimental groups. Very low background concentrations of zinc, boron, and aluminum were found to contaminate the sterile water as received from the manufacturer. Simulated compounding (manual or automated) in TPN bags did not contribute additional boron or aluminum but did result in a mean total zinc concentration of 35.4 micrograms/L; of this, 12.4 micrograms/L came from the compounding equipment, 9.1 micrograms/L from the TPN bag, and 13.9 micrograms/L from the sterile water for injection. Although the amount of zinc contributed by compounding was significantly higher than the background level, the amount was inconsequential compared with that needed to satisfy physiological requirements. Simulated compounding of TPN solutions either manually or with an automated system contributed minimal trace-element contamination.
 






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Society of Health-System Pharmacists.