Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Darbar, D
Right arrow Articles by Roden, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Darbar, D
Right arrow Articles by Roden, D.
American Journal of Health-System Pharmacy, Vol 53, Issue 6, 655-658
Copyright © 1996 by American Society of Health-System Pharmacists


Articles

Loss of quinidine gluconate injection in a polyvinyl chloride infusion system

D Darbar, S Dell'Orto, GR Wilkinson, and DM Roden


The effect of a polyvinyl chloride (PVC) i.v. administration system on the availability of quinidine gluconate was studied. Quinidine gluconate diluted in 5% dextrose injection was administered intravenously to five healthy volunteers via conventional PVC infusion sets, and the subjects received oral quinidine sulfate two days later. The mean +/- S.D. oral bioavailability of quinidine was, unexpectedly, greater than 100% (147 +/- 44%). To test the possibility that this occurred because of reduced delivery of i.v. quinidine, the percentage of drug delivered via two systems was evaluated in simulation studies, one involving a conventional PVC administration set and the other a glass syringe attached to shorter PVC tubing and a winged i.v. catheter. Spectrophotometric analysis revealed a 5-7% reduction in absorbance associated with loss of quinidine in the PVC infusion bag and a further 34-38% reduction in absorbance attributable to quinidine loss in the PVC tubing. However, with the winged i.v. catheter system the loss was reduced to less than 3%. More than 40% of a dose of quinidine gluconate was lost when the drug was administered with a conventional PVC i.v. administration set. Drug loss was reduced by using a winged i.v. catheter and shorter tubing.
 






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Society of Health-System Pharmacists.