Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carmenates, J
Right arrow Articles by Keith, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Carmenates, J
Right arrow Articles by Keith, M.
American Journal of Health-System Pharmacy, Vol 58, Issue 9, 779-783
Copyright © 2001 by American Society of Health-System Pharmacists


Articles

Impact of automation on pharmacist interventions and medication errors in a correctional health care system

J Carmenates and MR Keith


The implementation and impact of an automated check-and-sortation system in a correctional health care system are described. In February 1998 the Managed Health Care Division of the University of Houston College of Pharmacy submitted a proposal to the Texas State Board of Pharmacy for installing an automated check-and-sortation device in its distributive system serving Texas Department of Criminal Justice offenders. The new system would eliminate final visual verification of medication orders by pharmacists and thereby give them more time for in-depth reviews of patient profiles and for recommending clinical interventions. A vendor interested in developing a prototypic automated system was identified, and a disease management training course was developed to enable staff pharmacists to provide evidence-based pharmacotherapy recommendations. Twelve months of data before automation (February 1997 to January 1998) were compared with 16 months of postautomation data (June 1998 to September 1999). The number of clinical interventions increased from 396 per 100,000 medication orders filled before automation to 1075 per 100,000 orders after automation. Dispensing errors decreased from 6.3 to 4.1 per 100,000 medication orders filled. Identified filling errors increased from 224 to 256 per 100,000 orders. The reliability of the automated system was evidenced by a dispensing error rate of 0.6 per 100,000 orders. Implementation of an automated check-and-sortation device in a correctional health care system appeared to reduce dispensing errors and give pharmacists more time to review patient profiles and recommend clinical interventions.
 






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Society of Health-System Pharmacists.