Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Klein, M
Right arrow Articles by Carstens, G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Klein, M
Right arrow Articles by Carstens, G
American Journal of Health-System Pharmacy, Vol 60, Issue 10, 1006-1011
Copyright © 2003 by American Society of Health-System Pharmacists


Articles

Permeation of cytotoxic formulations through swatches from selected medical gloves

M Klein, N Lambov, N Samev, and G Carstens


The permeability of selected medical glove materials to various cytotoxic agents is described. Fifteen cytotoxic agents were prepared at the highest concentrations normally encountered by hospital personnel. Four single-layer and two double-layer glove systems made of two materials--latex and neoprene--were exposed to the drugs for 30, 60, 90, 120, 150, and 180 minutes. Circular sections of the glove material were cut from the cuff and evaluated without any pretreatment. Permeability tests were conducted in an apparatus consisting of a donor chamber containing the cytotoxic solution and a collection chamber filled with water (the acceptor medium). The two sections were separated by the glove material. Permeating portions, collected in water as the acceptor medium, were analyzed by either ultraviolet-visible light spectrophotometry or high-performance liquid chromatography (HPLC). Permeation rates were calculated on the basis of the concentration of the cytotoxic agent in the acceptor medium. Spectrophotometric measurements were taken every 30 minutes, and HPLC analysis was performed at the end of the three-hour period. Average permeation rates for 14 drugs were low (< 0.2 nmol/[min.cm2]) or no permeation was detected in all glove materials. All glove materials tested were impermeable to most of the cytotoxic agents over a period of three hours. Carmustine was the only agent that substantially permeated single-layer latex glove materials. Permeation of most tested cytotoxic formulations was low through swatches of material from various medical gloves.
 



This article has been cited by other articles:


Home page
Am J Health Syst PharmHome page
ASHP Guidelines on Handling Hazardous Drugs
Am. J. Health Syst. Pharm., June 15, 2006; 63(12): 1172 - 1191.
[Full Text] [PDF]


Home page
Am J Health Syst PharmHome page
P. E. Wallemacq, A. Capron, R. Vanbinst, E. Boeckmans, J. Gillard, and B. Favier
Permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions
Am. J. Health Syst. Pharm., March 15, 2006; 63(6): 547 - 556.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Society of Health-System Pharmacists.