Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Demers, J
Right arrow Articles by Hamilton, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Demers, J
Right arrow Articles by Hamilton, R.
American Journal of Health-System Pharmacy, Vol 60, Issue 11, 1130-1135
Copyright © 2003 by American Society of Health-System Pharmacists


Articles

Accuracy of home blood glucose monitors using forearm blood samples: FreeStyle versus One Touch Ultra

J Demers, MP Kane, G Bakst, RS Busch, and RA Hamilton


The accuracy of two home blood glucose monitors using forearm blood samples was studied. Blood samples were obtained from adults by venipuncture and analyzed for glucose concentration. Within five minutes after venipuncture, peripheral blood glucose measurements were taken in duplicate with the FreeStyle and One Touch Ultra monitors by using the same forearm as used for venipuncture. Accuracy was assessed by comparing the results for each first peripheral stick obtained by each monitor with the laboratory reference value. Monitor precision was evaluated by evaluating the mean difference in glucose values between the first and second peripheral sticks. Blood samples were obtained from 250 subjects, 170 (68%) of whom had diabetes mellitus. A total of 98.8% and 98.4% of the blood glucose readings obtained with FreeStyle and One Touch Ultra, respectively, were clinically acceptable, and 65.2% and 59.2% of the measurements, respectively, were within 10% of the laboratory reference values. The average difference between the first and second glucose measurements was 9.7 mg/dL for FreeStyle and 5.2 mg/dL for One Touch Ultra. One peripheral stick was needed to obtain an adequate blood sample in 95.6% of subjects using FreeStyle, compared with 83.2% of subjects using One Touch Ultra. Forearm blood glucose measurements obtained with the FreeStyle and One Touch Ultra devices were similar to laboratory reference values obtained by venipuncture.
 



This article has been cited by other articles:


Home page
Clin. Chem.Home page
J. Mahoney and J. Ellison
Assessing the Quality of Glucose Monitor Studies: A Critical Evaluation of Published Reports
Clin. Chem., June 1, 2007; 53(6): 1122 - 1128.
[Abstract] [Full Text] [PDF]


Home page
Am J Health Syst PharmHome page
S. M. Rivers, M. P. Kane, G. Bakst, R. S. Busch, and R. A. Hamilton
Precision and accuracy of two blood glucose meters: FreeStyle Flash versus One Touch Ultra.
Am. J. Health Syst. Pharm., August 1, 2006; 63(15): 1411 - 1416.
[Abstract] [Full Text] [PDF]


Home page
Journal of Pharmacy PracticeHome page
G. Vincze and A. Parthan
The Value of Home Monitoring Kits in Diabetes, Hypertension, Asthma, and Oral Anticoagulation Therapy
Journal of Pharmacy Practice, June 1, 2004; 17(3): 182 - 196.
[Abstract] [PDF]


Home page
Journal of Pharmacy PracticeHome page
A. L. Briggs and S. Cornell
Self-monitoring Blood Glucose (SMBG): Now and the Future
Journal of Pharmacy Practice, February 1, 2004; 17(1): 29 - 38.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Society of Health-System Pharmacists.