Advertisement
Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wilson, K
Right arrow Articles by Sullivan, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wilson, K
Right arrow Articles by Sullivan, M
American Journal of Health-System Pharmacy, Vol 61, Issue 2, 177-183
Copyright © 2004 by American Society of Health-System Pharmacists


Articles

Preventing medication errors with smart infusion technology

K Wilson and M Sullivan


PURPOSE: Processes that pharmacists can use to identify high-risk areas and drugs that require special focus in error-prevention efforts are discussed, with emphasis on the need for i.v. medication error prevention. SUMMARY: Pharmacists can help determine where best to focus medication safety efforts and innovative technology by identifying areas that pose the greatest risk of harm to a patient, such as medications, administration routes, patient care areas, and diagnosis-related groups. Delivery of i.v. medications via infusion devices has traditionally not been a major concern for pharmacists. The introduction of "smart" infusion technology has changed that paradigm by requiring pharmacist involvement in defining minimum and maximum doses for continuous and bolus infusions used within a health care facility. This technology provides a software filter to prevent key-stroke errors in programming infusion devices for delivery of i.v. drugs, as well as a new source of data with which to measure medication errors at the bedside. Implementation of smart infusion technology at Vanderbilt University Medical Center appeared to prevent errors involving heparin. In addition to having an immediate positive impact at the bedside, the technology was relatively easy to implement. CONCLUSION: Smart infusion systems represent an innovative technology that can provide an additional layer of protection at the point of care to help avert i.v. drug errors and prevent patient harm.
 



This article has been cited by other articles:


Home page
Am J Health Syst PharmHome page
L. C. Vermeulen, S. S. Rough, T. S. Thielke, R. R. Shane, M. F. Ivey, B. W. Woodward, P. G. Pierpaoli, S. M. Thomley, C. A. Borr, and D. A. Zilz
Strategic approach for improving the medication-use process in health systems: The high-performance pharmacy practice framework
Am. J. Health Syst. Pharm., August 15, 2007; 64(16): 1699 - 1710.
[Abstract] [Full Text] [PDF]


Home page
Am J Health Syst PharmHome page
C. K. Williams and R. R. Maddox
Implementation of an i.v. medication safety system
Am. J. Health Syst. Pharm., March 1, 2005; 62(5): 530 - 536.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Society of Health-System Pharmacists.
Advertisement