Advertisement
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McCluskey, S. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McCluskey, S. V.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?
American Journal of Health-System Pharmacy, Vol. 65, Issue 12, 1173-1176
Copyright © 2008. American Society of Health-System Pharmacists, Inc. All rights reserved. 1079-2082/04/0602-1242$06.00


Notes

Sterilization of glycerin

Susan V. McCluskey

SUSAN V. MCCLUSKEY, B.S.PHARM., is Production Laboratory Pharmacist, Mayo Pharmacy Services Production Laboratory, Mayo Clinic Rochester, 200 First Street SW, Rochester, MN 55902 (mccluskey.susan{at}mayo.edu).


Purpose. The sterilization of glycerin is described.

Summary. Glycerin is used in a wide variety of pharmaceutical formulations, including oral, otic, ophthalmic, topical, and parenteral preparations. Of the myriad uses for glycerin, some require a sterile solution. Due to the nature of dry heat sterilization with resulting equipment and validation needs, sterile filtration is the preferred sterilization method for glycerin at the Mayo Clinic Pharmacy Services Production Laboratory in Rochester, Minnesota. A practical procedure was attained with the use of a chemically compatible 0.22-µm capsule filter, peristaltic pump, and sterile tubing. The sterile tubing is attached firmly, with a twisting motion, to the hose barb ends of the filter. The peristaltic pump is set at minimum speed, and a sterile syringe is used to capture the sterile glycerin filtrate. After filtration, filter integrity testing using the bubble point test is performed on the filter used to sterilize the solution. Packaging was then completed by placing glycerin aliquots into unit-of-use sterile syringes, placing a sterile tip cap on each syringe, and labeling the syringe. End testing is needed for preparations, such as sterile glycerin, that are made from nonsterile components, regardless of sterilization technique. This quality-control testing includes but is not limited to visual checks, pH checks, and tests for bacterial endotoxins, particulate matter, and sterility. Beyond-use dating is then assigned based on chemical, physical, microbiological, and packaging considerations.

Conclusion. A practical method for sterilization of glycerin by compounding pharmacists is attainable through the use of membrane filtration. Sterility assurance is achieved through appropriate validation, and quality-control checks must be completed before release of the injectable preparation.

Index terms: Compounding; Control, quality; Excipients; Filters; Filtration; Glycerin; Sterile products; Sterility; Sterilization

 